Two methods for the reduction of nitrous oxide emissions, afterburning and reversed air staging, are investigated in a 12 MW circulating fluidized bed boiler. With afterburning the N 2O emission can be reduced by 90% or more, using an amount of secondary fuel corresponding to 10% of the total energy input. With reversed air staging it is possible to reduce the emission of N 2O to one fourth (25 ppm), without significantly affecting the other emissions. With reversed air staging no secondary air is used in the combustor and an air-ratio of about unity is maintained throughout the combustion chamber. Air for final combustion is added in the cyclone outlet.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.