Abstract

Postlime stabilization of municipal sludge requires methods for assessing the degree of lime incorporation and stability of the final product, as well as for evaluating and monitoring the performance of individual components in the process. The goal of this research was to systematically apply selected measures of lime incorporation and stability at the District of Columbia Water and Sewer Authority’s Blue Plains advanced wastewater treatment plant (see the companion paper). The transfer of sludge by screw conveyance prior to the lime blender did not appear to make it more difficult to incorporate lime in a bench-scale mixer. However, in the full-scale system, it may impede mixing by rolling the sludge into large plugs, and thus creating a discontinuous supply of sludge to the blender. Screw conveyance of limed sludge downstream from the blender appears to subject the limed sludge to additional mixing, resulting in improved lime incorporation and stabilization. The impact of lime purity (CaO%) appeared to...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.