Abstract

Methods for maintaining the temperature of the reheated steam at the TPP-110 twin-furnace boiler of the Novocherkassk GRES during operation at a lowered load are considered. It is shown taht the rated temperature of the steam superheat (545°C) can be ensured down to a boiler load of 40% of the nominal one through the redistribution of fuel and feedwater flowrates between the boiler casings and the delivery of flue gas recirculation in casing B.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.