Abstract

While less mature than the Li-ion battery, technologies based on Na, K, Mg, and Ca are attracting more and more attention from the battery community. New material (cathode, anode, or electrolyte) testing for these post-Li systems commonly involves the use of an electrochemical setup called a half-cell in which metal counter and reference electrodes are used. Here we first describe the different issues that become critical when moving away from Li with respect to the cell hardware (cell design, current collector, separator, insulator) and the nature of the counter and reference electrodes. Workarounds are given, and a versatile setup is proposed to run reliable electrochemical tests for post-Li battery materials in general, in a broad range of electrolyte compositions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.