Abstract

Absorbance- and fluorescence-based optical parameters are commonly used as surrogates in engineered systems, but there is no systematic approach for selecting robust parameters. This study develops a methodology that is applied to a case study of differentiating wastewater effluent organic matter from naturally-derived organic matter. The methodology defines criteria to identify optical parameters that could detect statistically significant compositional differences in organic matter, independent of organic matter concentration, and measure fluorescence-based parameters with low susceptibility to inner filter effects. The criteria were applied to 26 parameters that were measured for 11 pairs of source water and conventionally-treated wastewater samples collected from sites with varied spatial and temporal conditions. Only two parameters, apparent fluorescence quantum yield measured at excitation 370 nm and fluorescence peak ratio A:T, met the criteria across all sites. These results demonstrate and encourage an objective and robust process for selecting optical surrogates for organic matter characterization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.