Abstract
External fire spread between buildings is internationally considered as a major concern for buildings in dense urban environments. While design guidelines differ between countries, the fundamental methods currently used for limiting the risk of fire spread between buildings are generally limited to specifying the minimum required separation distance for a given unprotected facade area, or conversely, limiting the maximum allowable unprotected facade area for a given separation distance. The safety level associated with the current design guidelines is however unknown, making the implementation of innovative, safer and more cost-effective design solutions difficult. In order to assess the safety target implicitly incorporated in currently accepted design solutions, a methodology is developed for evaluating the annual probability of reaching unacceptable radiation intensities at the opposite facade. As a case study, the methodology is applied to a design which is in agreement with the current UK requirements specified in BR 187. This case study exposes inconsistencies in the current design guidelines, indicating the need for developing explicit safety targets.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.