Abstract

The work is devoted to the ultrasonic method of controlling mechanical stresses using ultrasonic head waves. The factors that contribute to the result of measurements of mechanical stresses include: the propagation velocity of the head ultrasonic wave, the temperature of the environment and the object of control, the coefficients of acoustoelastic and thermoacoustic coupling, parameters of the optical-acoustic transducer. The contribution of each of these factors to the results of measurements of mechanical stresses is assessed. A technique for assessing the uncertainty of measurements of mechanical stresses by the ultrasonic method using head waves has been developed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.