Abstract

Methylphosphonic acid (MPn) is suspected to play an important role in aquatic systems like rivers or the open ocean. To gain more insights into the importance of MPn, e.g., for the aquatic phosphorus cycle, an analytical method for its quantitative determination was developed. The method is based on the use of an isotopically-labelled internal standard and sample preparation including solid-phase extraction (SPE). Instrumental detection was done using GC-MS after derivatisation of MPn with N-tert-Butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). The study compares different isotopically-labelled compounds as well as different SPE-materials. As water samples with high salt content decrease the recovery of the chosen SPE-material, a desalting procedure using electrodialysis was implemented. Finally, water samples from different aquatic systems located at the German Baltic Sea coastal area were analysed to gain first insights into the relevance of MPn in these systems. MPn-concentrations in the low μg/L-range were detected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.