Abstract

Three types of high temperature fatigue tests are carried out for HR6W, which is one of the candidate materials for piping in an advanced ultra super critical (A-USC) power boiler operating over 700 °C steam condition. The first test is the isothermal fatigue test at 700 °C, the second one is the thermo-mechanical fatigue (TMF) test between 100 °Cand 700 °C under in-phase and out-of-phase conditions, the final one is the bithermal fatigue (BTF) test at 100 °C and 700 °C. The relations between the partitioned inelastic strain range determined by the strain range partitioning method and the life in those tests show good agreement, while the relations between the total strain range and the life show some differences.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.