Abstract
The storage of latent heat in phase change materials (PCM) is of great interest in many applications, for example in building applications. However, there is no standard method for the determination of the thermophysical properties of application-sized PCM specimens, i.e., specimens with sizes around 100 ml to 1000 ml. In order to close this metrological gap, a commercially available heat flow meter was modified to perform enthalpy measurements. The feasibility of this method was proven by performing comparative measurements on a stainless steel specimen using both the standard method DSC and the modified heat flow meter. Furthermore, measurements on a gypsum board with microencapsulated PCM were performed with the heat flow meter in order to determine the enthalpy. The coincidence with literature values is within ±4% which demonstrates that this method is a good choice for performing measurements on application-sized PCM specimens.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.