Abstract
An analytical method for the simultaneous quantitation of arseneous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and trimethylarsine oxide (TMAO) in human urine by coupling of high-performance liquid chromatography with hydride generation atomic absorption spectrometry (HPLC/HG-AAS) via a flow-injection interface is presented. After arsenic species separation by anion-exchange displacement chromatography the compounds are on-line reduced to their corresponding hydrides and detected by atomic absorption spectrometry. Detection limits range from 1.1 (TMAO) to 2.6 μg/L (As(V)). The method has been applied to determine arsenic species in the urine of a volunteer before and after consumption of seafood as well as to analyse certified reference urine samples for their arsenic species content.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.