Abstract

A method is considered to reach the air-tightness of the flange joint of the casing of an impeller pump with its cover using an anaerobic sealant instead of a gasket made of a thermoplastic material. The possible causes of leakage of working fluids that are related to the errors of machining flange surfaces and the specific features of their assembly are shown. The properties of anaerobic sealants that ensure the air-tightness of the flange joints are presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.