Abstract

The main objective of this research is to develop and validate a simple, specific, precise, sensitive, cost effective and rapid Reversed-Phase High-Performance Liquid Chromatographic (RP-HPLC) method for simultaneous quantification of Felodipine and Metoprolol in bulk and pharmaceutical dosage forms. The separation of the analytes were carried out on a X-bridge phenyl column with a moving phase composed of 0.1 % Tri ethyl amine: acetonitrile (30:70 v/v) delivered at a stream of 1.0 ml/min, and separation has been observed by UV detector, at a detection wavelength of 235 nm. This method was proven to be linear over a concentration limit of 10-150 µg/ml for Metoprolol, 2-30 µg/ml for Felodipine with correlation coefficient of 0.999. The retention time of Metoprolol and Felodipine were 2.936, 4.535 minutes respectively. To separate Metoprolol and Felodipine peaks a run time of 8 min. was used. The validation results were in good agreement with acceptable limits. RSD values which are less than 2.0 % indicating the accuracy and precision of this method. Hence it was evident that the proposed method was said to be a suitable one for the regular analysis and quality control of pharmaceutical preparations which contain these active drugs either individually or in combination.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call