Abstract
At the boundary layer's separation point, the mean of the shear stress drops to a small value while its fluctuation increases dramatically. Based on the thermal method, we can fabricate a MEMS-based shear stress sensor array to bend with the curved surface, which can measure the shear stress profile of the boundary layer. This paper presents two methods, mean and RMS of the shear stress difference max value and the second order of the array signals difference algorithm, to calculate the location of the flow separation point. Through combination of the two methods and analyzing the 2D circular column CFD simulation data, the position of the separation point can be determined accurately.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.