Counter-current chromatography (CCC) is a unique, liquid-liquid partition chromatography process. Both the mobile and stationary phases are liquids, so no solid support matrix is used. CCC has gained wide acceptance as a preparative technique in a variety of fields. Because the mobile and stationary phases are both liquids, gradient elution is difficult to perform with CCC. Phase equilibrium must be maintained, so any change in the composition of one phase may induce a compositional change in the other. In this work, a new linear gradient elution method was developed for CCC. Biphasic solvent systems containing heptane, ethyl acetate, methanol, and water (HepEMWat) in various ratios were prepared and used to optimize both isocratic and linear gradient CCC separation with methanol. We first separated a test mixture of four standard compounds with partition coefficients ranging from 0.8 to 7.8. The separation resembled a reversed-phase process, and elution was performed while progressively decreasing the polarity of the mobile phase. Target molecules with small partition coefficients eluted first in the lower phase of the optimized HepEMWat solvent system. Elution of constituents with large partition coefficients was quite slow under isocratic conditions. Separation time was significantly reduced when elution was performed with a linear gradient using methanol and the optimal HepEMWat system. Elution with a 3:7:4:6 (v/v/v/v) HepEMWat system took approximately 200 min. This included an 80-min isocratic step, followed by gradient elution with methanol from 0% to 30%. The optimized methanol linear gradient CCC method was then used to separate a complex mixture of natural products isolated from Sinopodophyllum hexandrum (Royle) Ying roots. Twelve compounds with a wide range of polarities were well-resolved in a single separation. We have developed a convenient and cost-effective strategy for the separation of complex mixtures. No tedious mobile phase preparation step is required. The volume of unused mobile phase is minimal, so little solvent is wasted. The method is an important advance for the separation of mixtures that contain many compounds with a large range of polarities and partition coefficients, which are common features of natural products.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.