Abstract

We developed a novel biaxial magnetoelectric (ME) gradiometer sensor system using Metglas/ Pb(Mg(1/3)Nb(2/3))O(3)-PbTiO(3) laminates for investigation of ac magnetic dipole detection. We demonstrate a detection sensitivity of 20 pT/√Hz in an open environment (unshielded) at quasi-static frequencies with a noise rejection efficiency of 23.5 dB, relative to a uniform external noise. In addition, a signal processing method was used to compute the magnetic field amplitude at a driven frequency of 7 Hz, and the results were also verified by theory. Practical testing and mathematical predictions show that there are only 7.2% and 4.2% gradiometric measurement errors in the x- and y-axis gradiometer components, enabling high-precision target detection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.