Abstract

We demonstrate a metastable helium Faraday optical filter operating on the 23S1 - 23P1 and 23S1 - 23P2 transition at 1083 nm by using a 3 cm long helium cell. The influence of the magnetic field and gas pressure of the helium cell on the filter characteristics is experimental studied. When the magnetic field is 230 Gs and the gas pressure of helium cell is about 110 Pa, the peak transmission corresponding to the two energy level transitions is about 32% and 57%, respectively. The equivalent noise bandwidth (ENBW) under this working condition is about 1.9 GHz. The metastable helium Faraday filter can be used to improve the optical inefficiency of a helium resonance fluorescence lidar to achieve the metastable helium density detection at 200-1000 km thermosphere.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.