Abstract

Abstract A gas cylinder, containing carbon dioxide (CO2) in a manifold of sixteen cylinders, exploded in an outdoor building construction site at midday within two hours of its arrival from a filling station. It was to be used for construction welding. The seamless gas cylinder that exploded was made of low alloy steel with a tempered martensitic microstructure. Observation revealed the presence of discreet localized external corrosion which weakened the gas cylinder extremely. A study concluded that the midday outdoor heat had apparently increased the pressure of the carbon dioxide gas within which in turn led to the sudden catastrophic explosion of the weakened corroded gas cylinder.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.