Abstract

Metallic particles with outer dimensions smaller than 100 microns in Li-ion battery cannot be detected using a conventional X-ray imaging system. We propose two systems using high Tc SQUIDs: One is a direct detection type and the other is an indirect type. In the direct detection system, an object with a contaminant is magnetized by a permanent magnet and then the remanent field of the contaminant is detected by SQUID. In the indirect detection system, the principle is based on Faradays law of electromagnetic induction. The diameter of the detection coil is 2 to 3 times larger than the SQUID; as a result, less number of SQUIDs, two or three is enough to inspect a specimen with a width of 65 mm. This method is applicable for an inspection of metallic contaminants in non-magnetic film such as a separator for Li-ion battery. We discuss the results of the evaluation of the new system as compared with a direct detection system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call