Abstract

Some modified ribonucleosides in biological fluids have been evaluated as cancer-related metabolites. Detection of endogenous modified ribonucleosides in biological fluids may serve as a noninvasive cancers diagnostic method. However, determination of modified ribonucleosides is still challenging because of their low abundance and serious matrix interferences in biological fluids. Here, we developed a novel strategy for comprehensive profiling of ribose conjugates from biological fluids using metal oxide-based dispersive solid-phase extraction (DSPE) followed with in vitro stable isotope labeling and double neutral loss scan-mass spectrometry analysis (DSPE-SIL-LC-DNLS-MS). Cerium dioxide (CeO2) was used to selectively recognize and capture ribose conjugates from complex biological samples under basic environment. The enriched ribose conjugates were subsequently labeled with a pair of isotope labeling reagents (acetone and acetone-d6). The glucosidic bond of acetone labeled ribose conjugates is readily ruptured, and the generated ribose that carries an isotope tag can be lost as a neutral fragment under collision induced dissociation (CID). Since the light (acetone) and heavy (acetone-d6) labeled compounds have the same chemical structures and can generate different neutral loss fragments (NL 172 and 178 Da), it is therefore highly convenient to profile ribose conjugates by double neutral loss scan mode in mass spectrometry analysis. In this respect, the light and heavy labeled compounds were ionized at the same condition but recorded separately on MS spectra, which can significantly improve the detection specificity and facilitate the identification of ribose conjugates. Using the developed DSPE-SIL-LC-DNLS-MS strategy, we profiled the ribose conjugates in human urine, and 49 ribose conjugates were readily identified, among which 7 ribose conjugates exhibited significant contents change between healthy controls and lymphoma patients. The DSPE-SIL-LC-DNLS-MS strategy combines the selective enrichment, stable isotope labeling, and double neutral loss scan - MS analysis, which therefore can efficiently minimize false positive results, facilitate the relative quantification, and notably increase the numbers of identified ribose conjugates in biological fluids samples. Taken together, this study established a promising strategy for the effective profiling of urinary modified ribonucleosides, and simultaneous evaluation of the contents change of multiple modified ribonucleosides should provide more accurate and conclusive results for the use of urinary modified ribonucleosides as indicators of cancers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.