Abstract
BackgroundDifferent fixation methods in anterior cruciate ligament reconstruction (ACLR) have been associated with different revision rates, specifically in the early postoperative period. However, most previous research has either grouped together different fixation types or evaluated femoral-sided fixation or tibial-sided fixation separately. Therefore, the purpose of this study was to determine ACL revision rates for specific combinations of femoral and tibial fixation methods within 2 years of primary hamstring tendon autograft ACLR based on data from the Swedish National Knee Ligament Registry (SNKLR).MethodsPatients that underwent primary hamstring tendon autograft ACLR between 2005 and 2018 in the SNKLR were included. The collected data included patient characteristics (age, sex, body mass index [BMI]), activity at time of injury, surgical information (concomitant injuries, time from injury to surgery, fixation types at the femur and tibia), and subsequent revision ACLR. Revision rate within 2 years of the index procedure was chosen, as ACLR fixation is most likely to contribute to ACLR revision within the first 2 years, during graft maturation.ResultsOf the 23,238 included patients undergoing primary hamstring ACLR, 581 (2.5%) underwent revision ACLR within 2 years of the index procedure. Among the combinations used for > 300 patients, the femoral metal interference screw/tibial metal interference screw fixation combination had the highest revision rate followed by metal interference screw/resorbable screw and Endobutton/AO screw fixation combinations, with respective revision rates of 4.0, 3.0, and 3.0%. The lowest revision rate within 2 years of ACLR was found in the Endobutton/metal interference screw with backup Osteosuture fixation combination, used in 433 cases, with a failure rate of 0.9%.ConclusionDifferent early ACL revision rates were found across different combinations of femoral and tibial fixation devices within 2 years of primary hamstring tendon autograft ACLR. Metal interference screw fixation, particularly when performed on both the femoral and tibial sides, most frequently resulted in revision ACLR. These findings may be helpful for surgeons in selecting appropriate fixation devices for hamstring ACLR.Level of evidenceIV
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.