Abstract

An investigation was conducted into a failure of convection section tubes in a process gas heater in a steel-making company. Thorough study using various characterisation techniques showed that the failure of the tubes, which were made of low-alloyed steel ASTM A335 P22, was attributed to metal dusting. The attack was accelerated because of the use of incompatible tube material for the intended operating conditions. Moreover, thermal fatigue cracks were discovered on the tube surfaces. Such cracks might have been caused by the high number of plant start-ups and shutdowns. Failure contributing factors and recommendations to avoid similar failure are discussed in this article.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.