Equilibrium vacancy concentrations in metal specimens are measured as a function of temperature by observing trapping of positrons emitted by a 19Ne source. The inert gas source, which is generated continuously by an electron linac, permits the extension of vacancy formation energy measurements to metals of high melting point, e.g. Ni, Fe, Mo, Nb etc.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.