Abstract

Granite aggregates are known to be the radon source in concrete. Recently, metakaolin has been introduced as a partial substitution of Portland cement to produce high strength concrete. It can effectively reduce the porosity of both the matrix and the aggregate/paste transition zone, which suggests its ability to retard radon emission from concrete aggregates. In the present work, radon exhalation rates from concrete cubes substituted with metakaolin were measured using charcoal canisters and gamma spectroscopy, and were considerably lower than those from normal concrete, by about 30%. The indoor radon concentration reduction is estimated as approximately 9 Bq m(-3) calculated using a room model, causing a 30% reduction in the indoor radon concentration and the corresponding radon dose. Therefore, metakaolin is a simple material to reduce the indoor radon concentration and the radon dose.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.