Abstract

The aim of this meta-analysis is to evaluate the central corneal thickness (CCT) measurement differences between Pentacam (Oculus Inc., Germany) and Ultrasound Pachymetry (USP) in normal (unoperated eyes , myopic and astigmatic eyes without corneal disease or topographic irregularity), after laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), and keratoconic or keratoconus suspected eyes. We assess whether Pentacam and USP have similar CCT differences in normal, thinner corneas after LASIK or PRK procedures, and kerotoconic or keratoconus suspected eyes. Data sources, including PubMed, Medline, EMBASE, and Cochrane Central Registry of Controlled Trials on the Cochrane Library, were searched to find the relevant studies. Primary outcome measures were CCT measurement between Pentacam and USP. Three groups of eyes were analyzed: normal; LASIK or PRK eyes; and keratoconus suspected or keratoconic eyes. Nineteen studies describing 1,908 eyes were enrolled in the normal group. Pentacam results were 1.47μm ,95% confidence interval (CI) -2.32 to 5.27, higher than USP without statistically significant difference (P = 0.45). Nine studies with total 539 eyes were included in the corneas after LASIK or PRK. The mean difference in the CCT measurement with Pentacam and ultrasound pachymetry was 1.03μm, with the 95% CI -3.36 to 5.42, there was no statistically difference (P = 0.64). Four studies with a total of 185 eyes were included in the keratoconic eyes or keratoconus-suspect group, however,the mean difference was -6.33μm (95% CI -9.17 to-3.49), which was statistically different between Pentacam and ultrasound pachymetry in the CCT measurement (P < 0.0001). Pentacam offers similar CCT results to ultrasound pachymetry in normal eyes, thinner corneas after LASIK or PRK procedures. However, in keratoconic or keratoconus-suspect eyes, Pentacam slightly underestimates the central corneal thickness than does ultrasound pachymetry, which may result from the difficulty in fixation of keratoconic eyes, misalignment of Pentacam and the variation of ultrasonic velocity due to the histological deformation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call