Abstract

Objective: To analyze the accuracy and specificity of recent studies to compare the ability of predicting fluid responsiveness with Passive Leg Raising (PLR) by using invasive or non-invasive techniques during passive leg raising. Data Sources: MEDLINE, EMBASE and the Cochrane Database of Systematic Reviews were systematically searched. Study Selection: Clinical trials that reported the sensitivity, specificity and area under the receiver operating characteristic curve (AUC) between the responder and non-responder induced by passive leg raising and Volume Expansion (VE) in critical ill patients were selected. 246 studies were screened, 14 studies were included for data extraction, which met our inclusion criteria. Data Extraction: Data were abstracted on study characteristics, patient population, type and amount of VE, time of VE, definition of responders, position, techniques used for measuring hemodynamic change, number and percentage of responders, the correlation coefficient, sensitivity, specificity, best threshold and area under the ROC curve (AUC). Meta-analytic techniques were used to summarize the data. Data Synthesis: A total of 524 critical ill patients from 14 studies were analyzed. Data are reported as point estimate (95% confidence intervals). The pooled sensitivity and specificity of invasive techniques were 80% (73% - 85%) and 89% (84% - 93%) respectively with the area under the sROC of 0.94. While, the pooled sensitivity and specificity of non-invasive techniques were 88% (84% - 92%) and 91% (86% - 94%) respectively with the area under the sROC of 0.95. The pooled DOR of invasive techniques was 32.2 (13.6 - 76.8), which was much lower than that of non-invasive techniques with the value of 64.3 (33.9 - 121.7). Conclusions: The hemodynamic indexes changes induced by PLR could reliably predict fluid responsiveness. Non-invasive hemodynamic techniques with their accuracy and safety can benefit the daily work in ICUs. Because the number of patients included in the present trials was small, further studies should be undertaken to confirm these findings.

Highlights

  • Fluid therapy is an essential part in Intensive Care Unit (ICU) to survive patients with hypovolemia

  • To analyze the accuracy and specificity of recent studies to compare the ability of predicting fluid responsiveness with Passive Leg Raising (PLR) by using invasive or non-invasive techniques during passive leg raising

  • Study Selection: Clinical trials that reported the sensitivity, specificity and area under the receiver operating characteristic curve (AUC) between the responder and non-responder induced by passive leg raising and Volume Expansion (VE) in critical ill patients were selected. 246 studies were screened, 14 studies were included for data extraction, which met our inclusion criteria

Read more

Summary

Introduction

Fluid therapy is an essential part in Intensive Care Unit (ICU) to survive patients with hypovolemia. Studies have shown that about 50% of critically ill patients do not exhibit the desired effect [1]. How to assess intravascular volume accurately has been a critical problem. Passive Leg Raising (PLR) is a reversible maneuver that mimics rapid Volume Expansion (VE) by shifting venous blood from the lower limbs toward the intrathoracic compartment [2]. PLR has been validated to predict fluid responsiveness, but it requires the determination of CO or its surrogates with a fast-response device, because the hemodynamic changes may be transient [3] [4]

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.