Abstract
Mesh migration after laparoscopic inguinal hernia repair is an unusual complication. We report a case of a 45-year-old man with persistent discharging of abdominal wall sinus after total extraperitoneal inguinal hernia repair. The patient underwent exploration and excision of the sinus tract with removal of the embedded mesh. A part of the mesh had migrated into the urinary bladder. Partial cystectomy with excision of wall containing the mesh was performed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.