Abstract

At the request of the Minnesota Power, Inc., the Energy & Environmental Research Center (EERC) sampled for lead at the stack (or duct directly leading to the stack) for three units at the Boswell Energy Center. All sampling was done in triplicate using U.S. Environmental Protection Agency (EPA) Method 12, with sampling procedures following EPA Methods 1 through 4. During the test program, lead sampling was done using EPA Method 12 in the duct at the outlet of the baghouse serving Unit 2 and the duct at the outlet of the wet particulate scrubber serving Unit 3. For Unit 4, lead sampling was done at the stack. The specific objective for the project was to determine the concentration of lead in the flue gas being emitted into the atmosphere from the Boswell Energy Center. The test program was performed during the period of May 8 through 11, 2000. This report presents the test data, sample calculations, and results, and a discussion of the lead sampling performed at the Boswell Energy Center. The detailed test data and test results, raw test data, process data, laboratory reports, and equipment calibration records are provided in Appendices A, B, and C.