Abstract

This paper presents a novel operation mechanism for ultrasonic testing in-water. The mechanism employs the surface-tension forces between the water and ultrasonic probe surfaces to cause an elongation (meniscus) of the water column and thus focuses the ultrasonic beam. The proposed meniscus-mode operation mechanism exploits this phenomenon to amplify the ultrasonic signal in comparison to the traditional fully-immersed setup. The visualization of the proposed mechanism is presented with the aid of finite-element simulations. In addition, the ultrasonic signal amplification due to operation in meniscus-mode is demonstrated experimentally using a capacitive micromachined ultrasonic transducer (CMUT) fabricated in PolyMUMPs technology. A factor of ∼2.24× improvement in the ultrasonic signal strength is measured.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.