Abstract

Many meniscal fixation implants provide only low pull out forces between 15 and 50 N. However, it is unknown if these forces are sufficient to withstand the loads, which occur in vivo. The aim of this laboratory study was to explore the gapping behavior of longitudinal meniscal tears. It was also investigated to what extent a fixation implant of low pull out force is able to reduce the gaps that occur in meniscal tears under different loading conditions. Methods: Longitudinal tears of 2 cm in length were set in the posterior horn of the medial menisci of 8 porcine knee joints. To observe the tears an opaque placeholder of the same shape as the original articular surface replaced the medial tibial plateau. Thus the menisci could be visualized in situ. The knees were exposed to flexion-extension cycles in a loading and motion simulator under 30 N and 200 N axial joint load, under tibial rotation moments, varus or valgus moments, and combined moments. For each load condition the maximum gap width of the tear occurring during a motion cycle was recorded. All tests were repeated after lengthening the initial tear to 2.5 cm, and subsequently to 3 cm. Finally the tears were repaired using three Meniscal Screws in each knee and the test repeated. Results: Maximum gapping of 1.6 mm (Standard deviation (SD) 0.5 mm) occurred for the 3 cm tear under 200 N axial joint load under a valgus-external tibial rotation moment. Significantly less gapping was observed under pure internal tibial rotation for all tear lengths and axial loads (between 0.1 mm (SD 0.28 mm) and 0.9 mm (SD 0.3 mm); P < .05). Longer tears always produced broader tear gaps (P < .05). Repair with three Meniscal Screws reduced the maximum width of the tear gaps significantly (P < .05). The gaps were very small especially at the locations of the implants with gap widths of 0.28 mm (SD 0.45 mm) under a varus moment and 200 N axial joint load. The gapping between the implants was also reduced with a maximum gap of 0.62 mm (SD 0.52 mm) under external tibial rotation and 30 N axial joint load. Discussion: From the gap widths measured in this study and the stiffness of the implant-meniscus interface determined in previous studies maximum forces of the implant-meniscus interface of 10 N can be estimated. This coincides with the findings of Kirsch et al. (J Biomech 1999;Suppl 1:104), who measured low forces in meniscal sutures. Therefore the implant pull out force seems not to be a critical parameter. In conclusion, it can be assumed that all available meniscal fixation implants provide sufficient primary stability avoiding excessive gapping even under critical joint loads like valgus and external tibial rotation. Early rehabilitation under weight bearing can therefore be recommended. Nevertheless, to avoid peak gapping of repaired meniscal tears a brace limiting external rotation can be worn.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.