Abstract

In this paper, we analysis the working principle of a cilium-type MEMS vector hydrophone, by analyzing we obtained the errors of the vector micro-sensor are deviations from column cilium. Since the structure is mainly picking up sound vibrations by the cilium, the piezoresistor which on the beams connected by Wheatstone bridge circuit will output the signals, so the deviation of cilium cylinder have greater impact the sensitivity in both directions of vector hydrophone. Through theoretical calculation and finite element simulation of the sensitive structure of the error analysis. By the structure of the hydrophone error test ,we obtained the sensitivity of X direction is 0.755mv / g, the sensitivity of Y direction is 0.683mv / g, The relative sensitivity error of two directions is 9.5% which is close to the simulation results. Finally, this paper give a solution to the error. (Abstract)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.