Abstract

To evaluate the applicability of filtration membranes for detecting Alicyclobacillus spp. spores in apple juice. Ten types of nitrocellulose membrane filters from five manufacturers were used to collect and enumerate five Alicyclobacillus spore isolates and results were compared to conventional K agar plating. Spore recovery differed among filters with an average recovery rate of 126.2%. Recovery levels also differed among spore isolates. Although significant difference (P < 0.05) in spore sizes existed, no correlation could be determined between spore size and membrane filter recovery rate. Recovery of spores using membrane filtration is dependent on the manufacturer and filter pore size. Correlations between spore recovery rate and spore size could not be determined. Low numbers of Alicyclobacillus spores in juice can be effectively detected using membrane filtration although recovery rate differences exist among different manufacturers. Use of membrane filtration is a simple, fast alternative to the week-long enrichment procedures currently employed in most quality assurance tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.