Abstract

Early use of targeted radionuclide therapy to eradicate tumor cell clusters and micrometastases might offer cure. However, there is a need to select appropriate radionuclides and assess the potential impact of heterogeneous targeting. Methods: The Monte Carlo code CELLDOSE was used to assess membrane and nuclear absorbed doses from 177Lu and 161Tb (β--emitter with additional conversion and Auger electrons) in a cluster of 19 cells (14-μm diameter, 10-μm nucleus). The radionuclide distributions considered were cell surface, intracytoplasmic, or intranuclear, with 1,436 MeV released per labeled cell. To model heterogeneous targeting, 4 of the 19 cells were unlabeled, their position being stochastically determined. We simulated situations of single targeting, as well as dual targeting, with the 2 radiopharmaceuticals aiming at different targets. Results: 161Tb delivered 2- to 6-fold higher absorbed doses to cell membranes and 2- to 3-fold higher nuclear doses than 177Lu. When all 19 cells were targeted, membrane and nuclear absorbed doses were dependent mainly on radionuclide location. With cell surface location, membrane absorbed doses were substantially higher than nuclear absorbed doses, both with 177Lu (38-41 vs. 4.7-7.2 Gy) and with 161Tb (237-244 vs. 9.8-15.1 Gy). However, when 4 cells were not targeted by the cell surface radiopharmaceutical, the membranes of these cells received on average only 9.6% of the 177Lu absorbed dose and 2.9% of the 161Tb dose, compared with a cluster with uniform cell targeting, whereas the impact on nuclear absorbed doses was moderate. With an intranuclear radionuclide location, the nuclei of unlabeled cells received only 17% of the 177Lu absorbed dose and 10.8% of the 161Tb dose, compared with situations with uniform targeting. With an intracytoplasmic location, nuclear and membrane absorbed doses to unlabeled cells were one half to one quarter those obtained with uniform targeting, both for 177Lu and for 161Tb. Dual targeting was beneficial in minimizing absorbed dose heterogeneities. Conclusion: To eradicate tumor cell clusters, 161Tb may be a better candidate than 177Lu. Heterogeneous cell targeting can lead to substantial heterogeneities in absorbed doses. Dual targeting was helpful in reducing dose heterogeneity and should be explored in preclinical and clinical studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call