Abstract
Melt pool temperature is of great importance to deposition quality in laser metal deposition processes. To control the melt pool temperature, an empirical process model describing the relationship between the temperature and process parameters (i.e., laser power, powder flow rate, and traverse speed) is established and verified experimentally. A general tracking controller using the internal model principle is then designed. To examine the controller performance, three sets of experiments tracking both constant and time-varying temperature references are conducted. The results show the melt pool temperature controller performs well in tracking both constant and time-varying temperature references even when process parameters vary significantly. However a multilayer deposition experiment illustrates that maintaining a constant melt pool temperature does not necessarily lead to uniform track morphology, which is an important criteria for deposition quality. The reason is believed to be that different melt pool morphologies may have the same temperature depending on the dynamic balance of heat input and heat loss.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.