Abstract

Novel polymeric composites for radiation dosimetry were developed. The composites were prepared by solvent-free melt compounding of ethylene vinyl acetate (EVA) (40% vinyl) and magnesium sulfate (MgSO4). Mechanical properties, melt flow characteristics and dosimetric properties were investigated. The composites with up to 50% (wt) of MgSO4 were flexible and capable of flow. The dose response of the EPR signal of the composites was studied in the dose range 3Gy–4kGy and found to be linear between 18Gy and 4kGy. The reproducibility of dose measurements was good. The signal fading rate and the energy dependence of the dose response were found to be acceptable.