Abstract

BackgroundThe detection of tyrosine kinase inhibitors (TKIs) in biological fluids is essential due to their critical role in cancer therapy and the variability in individual drug metabolism, which necessitates precise dosing. Traditional methods for analyzing TKIs in biological fluids, such as blood plasma, typically involve complex sample preparation techniques that can be resource-intensive, environmentally burdensome, and not sufficiently sensitive for low-concentration analytes. There is a pressing need for more efficient, economical, and environmentally friendly methods that can enhance sensitivity and throughput without compromising accuracy. ResultsThis study explores the use of melt-blown polypropylene nonwoven (MBPP), commonly found in face masks, as a novel sorbent for pipette-tip micro-solid phase extraction (PT-μSPE). MBPP demonstrated excellent hydrophobicity and significant mesoporous adsorption capacity. An extraction device was fashioned by inserting a segment of MBPP (15 mg) into a 200 μL disposable plastic pipette tip, which was then attached to a 2.5 mL disposable plastic syringe. The MBPP's fabric form removes the need for a frit, allowing the extraction process to be completed in just 3 min through simple plunger manipulation. The method achieved extraction recoveries ranging from 60.5 % to nearly 100 %. Subsequent method validation using liquid chromatography-tandem mass spectrometry (LC-MS/MS) showed satisfactory linearity (coefficient of determination R2 > 0.993), accuracy (relative recoveries: 86.3%–114.8 %), and precision (relative standard deviation: 3.4%–11.3 %), with detection limits between 0.022 and 0.135 ng mL−1. SignificanceThe introduction of MBPP for PT-μSPE represents a significant advancement in the bioanalytical detection of TKIs, offering a highly efficient, cost-effective, and environmentally sustainable method. It compares favorably with existing techniques, offering advantages in terms of cost, environmental impact, and ease of use. This approach has the potential to be widely adopted for routine monitoring of TKIs in clinical settings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.