Abstract
A MELCOR input model of the divertor components and associated heat transfer system has been developed in order to analyse the divertor ex-vessel LOCA that potentially could result in radioactive releases to the environment. This paper presents the results of some parameter studies related to the DV ex-vessel LOCA: (i) three different in-vessel break sizes: one toroidal ring break with a size of 0.32 m 2, one-half ring break of 0.16 m 2 and one-quarter ring break of 0.08 m 2. (ii) Two different ex-vessel break locations were used: before heat exchanger and after heat exchanger but before pump.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.