Abstract

Purpose: To evaluate the morphology changes of meibomian glands (MGs) after cataract surgery.Setting: Hangzhou Branch of the Eye Hospital of Wenzhou Medical University, Zhejiang, China.Methods: In this contra-lateral eye study, 40 patients received unilateral cataract surgery for age-related cataract. All the patients underwent the evaluation of non-invasive break-up time (NIBUT) and lower tear meniscus height (TMH) before the surgery and 6 months post-operatively. The MGs were evaluated via ImageJ and Meibomian Gland Bio-image Analyzer. MG dropout, length, width, area, gland diameter deformation index (DI), and gland signal index (SI) were recorded.Results: MG length, width, area, DI, and SI were significantly decreased after cataract surgery in the study group (operated eyes, P < 0.001, P = 0.003, P < 0.001, P = 0.001, and P < 0.001, respectively) and showed no significant changes in the control group (non-operated eyes) (all P > 0.05). MG loss increased more in the study group (P = 0.030), and the changes in TMH and NIBUT were not significantly different between the two eyes (both P > 0.05).Conclusion: Cataract surgery aggravated meibomian gland morphology, such as MG loss, MG length, width, area, and SI, and produced no change in NIBUT and TMH at 6 months post-operatively.

Highlights

  • Phacoemulsification with intraocular lens implantation is a standard procedure for the treatment of cataract

  • meibomian gland (MG) morphology was evaluated by the Meibomian Gland Morphology Changes grade of MG loss, and no quantitative parameters for each gland were assessed in their study

  • No significant differences were found between the two groups in tear meniscus height (TMH), non-invasive break-up time (NIBUT), and MG parameters except for MG length

Read more

Summary

Methods

In this contra-lateral eye study, 40 patients received unilateral cataract surgery for age-related cataract. All the patients underwent the evaluation of non-invasive break-up time (NIBUT) and lower tear meniscus height (TMH) before the surgery and 6 months post-operatively. The MGs were evaluated via ImageJ and Meibomian Gland Bio-image Analyzer. MG dropout, length, width, area, gland diameter deformation index (DI), and gland signal index (SI) were recorded

Results
Conclusion
INTRODUCTION
RESULTS
DISCUSSION
ETHICS STATEMENT
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call