It is proposed that use of a 'standard' activation energy (in the range of 0.6 to 0.8 eV), selected by consensus, be adopted as an acceptable method of thermal aging analysis of safety-related equipment; the rationale for this proposal is given. Minor improvements of current practices for simulating the functional degradation of other stresses are suggested. It is recommended that utilities establish schedules for reevaluation of qualified life on the basis of operating experience and that such evaluations be documented. It is further recommended that more effort be placed on degradation monitoring. Adoption of these recommendations is expected to redistribute the cost of equipment qualification into more productive avenues. Ultimately, they are expected to provide increased assurance of plant safety coupled with increased reliability and availability and reduced operating costs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.