Abstract
Pleuroscopy, also known as medical thoracoscopy (MT), is an important tool for pleural disease management. Removal of foreign body (FB) by MT was reported in a few reports because it can identify the position of a FB in the pleural cavity and can be used for its urgent removal. In this study, we describe the case of a male patient with a ruptured lung abscess and a rare complication of self-expandable metallic stent (SEMS) migration into the pleural cavity via a bronchopleural fistula after the management of obstructive airway disease. An experienced pulmonologist successfully removed the SEMS from the pleural cavity using semi-rigid pleuroscopy under local anesthesia and conscious sedation in a bronchoscopy suite.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.