Abstract
Background. Postoperative mediastinal false aneurysm is associated with a substantial morbidity and mortality. Surgical treatment is mandatory, although the individual approach varies according to the type of pathologic process, infection status, and site of origin of the aneurysm. Methods. Between April 1993 and February 1999, we treated 10 patients, aged 25 to 73 years, with anastomotic mediastinal false aneurysm originating from the proximal thoracic aorta. Nine had undergone prior operations on the ascending aorta (7, type A dissection repair; 1, aortitis; 1, root abscess) with a Dacron conduit (n = 5) or valved conduit (n = 4). The last patient had undergone valve replacement for excavating aortic root sepsis. False aneurysms were detected from 2 to 70 months after the most recent operation. Three patients had positive tissue cultures. The surgical procedure was direct suture repair of the disrupted anastomosis in 5, root or ascending aortic replacement with an aortic homograft in 4, and Dacron graft interposition in 1. Hypothermic low-flow perfusion with or without circulatory arrest was used in all patients. Results. There was one hospital death caused by staphylococcal mediastinitis. A false aneurysm recurred after direct suture repair in 2 patients with underlying type A dissection or aortitis. This resulted in one late death. One patient experienced a neurologic event during removal of an infected vascular graft. All 8 surviving patients are alive and well after a mean follow-up of 2 years. Three patients with mycotic false aneurysms remain free from infection after aortic homograft replacement. Conclusions. Mediastinal false aneurysms are surgically taxing. Low-flow hypothermic perfusion with or without circulatory arrest allows safe reentry. Radical surgery provides a satisfactory outcome in infected patients. Local repair of suture dehiscence in pathologic tissues may predispose to recurrence. We suspect that excessive use of formalin in gelatin-resorcin-formol glue may predispose to tissue necrosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.