Abstract

The use of a tracheo-esophageal voice prosthesis is a well-established procedure to restore the voice in total laryngectomees. The insertion of the prosthesis is not a risk-free procedure, various complications having been reported especially in irradiated patients. Here described is a case of an esophageal rupture after secondary tracheo-esophageal puncture with mediastinal abscess in a patient previously treated with pharyngo-laryngectomy and subsequent radiotherapy for a left pyriform sinus carcinoma, which required immediate surgical drainage through a left cervical approach. Few weeks after surgical drainage an esophageal stricture at the site of the rupture developed, which was only temporarily resolved after the insertion of biodegradable esophageal stents, followed by re-stenosis once the reabsorption of the stent took place.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.