Abstract

The purpose of this study was to evaluate the functional outcomes of medialized rotator cuff repair and the continuity of repaired tendon in chronic retracted rotator cuff tears. Thirty-five consecutive patients were selected from 153 cases that underwent arthroscopic rotator cuff repair for more than medium-sized posterosuperior rotator cuff tears between July 2009 and July 2012 performed with the medialized repair. All cases were available for at least 2 years of postoperative follow-up. The visual analog scale of pain, muscle strength, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and University of California-Los Angeles score were evaluated. At the final follow-up, all clinical outcomes were significantly improved. The visual analog scale score for pain improved from 6 ± 1 preoperatively to 2 ± 1 postoperatively. The range of motion increased from preoperatively to postoperatively: active forward elevation, from 134° ± 49° to 150° ± 16°; active external rotation at the side, from 47° ± 15° to 55° ± 10°; and active internal rotation, from L3 to L1. The shoulder score also improved: Constant score, from 53.5 ± 16.7 to 79 ± 10; American Shoulder and Elbow Surgeons score, from 51 ± 15 to 82 ± 8; and University of California-Los Angeles score, from 14 ± 4 to 28 ± 4. The retear cases at the final follow-up were 6 (17%). Medialized repair may be useful in cases in which anatomic bone-to-tendon repair would be difficult because of the excessive tension of the repaired tendon and a torn tendon that does not reach the anatomic insertion.