Abstract

The reported rate of isolated medial orbital wall fractures varies widely but has been found to be as high as 55% of all orbital fractures. Identifying and repairing medial orbital wall defects by using appropriate materials improves patient outcome considerably; however, most related research has focused on orbital floor defect management rather than medial orbital wall treatment, and no consensus on repairing medial orbital wall fractures exists. Furthermore, medial orbital wall fracture is a main cause of posttraumatic enophthalmos. In this study, we introduce a modified surgical technique for repairing large medial wall fractures stably, also reviewed relevant literature and established an algorithm for managing medial orbital wall fractures. We reviewed the outcomes of facial trauma patients who underwent facial bone reduction and internal fixation surgery in our hospital between October 1, 2010, and October 1, 2013. The patients were all treated medial orbital wall reconstruction with porous polyethylene by using a transconjunctival approach with a caruncular extension for large medial orbital wall fractures. Medical records and radiologic images of the patients were reviewed retrospectively. The outcomes evaluated were trauma mechanism, clinical findings of ocular injury, preoperative and postoperative ocular symptoms, degree of enophthalmos, and orbital volume restoration after surgery. Transconjunctival approach with a caruncular extension was performed without any complications. The incidence of diplopia was 47.4% and enophthalmos (>2 mm) was 31.6%, with no significant diplopia and enophthalmos after surgery. Patients were symptom-free on follow-up. The average enophthalmos was successfully corrected from 0.88 mm preoperatively to 0.26 mm and orbital volume was corrected from 26.22 to 22.99 cm after surgery; these results also showed P less than 0.001. The current results suggest that the proposed method of medial orbital wall reconstruction, in which porous polyethylene is implanted by using a transconjunctival approach with a caruncular extension, yields favorable outcomes. The approach facilitates a wide visualization of the operative field, which provides sufficient working space for implant insertion and is consequently free from iatrogenic trauma or surgery-related complications.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call