This report presents our results in a low-temperature mechanochemical hydrodechlorination process applied to fly ash coming from a municipal waste incinerator in order to efficiently remove all traces of PCDDs, PCDFs and PCBs. We found that the most suitable degradation agent is a mixture of metallic calcium and calcium oxide. A sample of fly ash presenting a TEQ of 5200 pg g −1 was completely detoxified (no traces of PCDDs, PCDFs and PCBs detected) after ball-milling at 400 rpm over night.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.