Abstract
The mechanistic modeling of preparative liquid chromatography is still a challenging task. Nonideal thermodynamic conditions may require activity coefficients for the mechanistic description of preparative chromatography. In this work, a chromatographic cation exchange step with a polypeptide having a complex elution behavior in low and high loading situations is modeled. Model calibration in the linear range of the isotherm is done by applying counterion-induced linear gradient elution experiments between pH3.3 and 4.3. Inverse fitting with column loads up to 25mg/mLCV is performed for parameter estimation in the nonlinear range. The polypeptide elution peak shows an anti-Langmuirian behavior with fronting under low loading conditions and a switch to a Langmuirian behavior with increasing load. This unusual elution behavior could be described with an extended version of the sigmoidal Self-Association isotherm including two activity coefficients for the polypeptide and counterion in solution. The activity coefficient of the solute polypeptide shows a strong influence on the model parameters and is crucial in the linear and nonlinear range of the isotherm. The modeling procedure results in a unique and robust model parameter set that is sufficient to describe the complex elution behavior and allows modeling over the full isotherm range.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have