Abstract

To study the mechanism of increase in the mitral valve area (MVA) and the anatomic features of the mitral valve that may affect the results of catheter double-balloon valvuloplasty (CBV) in adult patients with mitral stenosis, Doppler and two-dimensional echocardiography was performed in 12 patients before and immediately after CBV. Immediately after CBV, there was an increase in the transverse diameter of the mitral valve orifice from 18 +/- 1.6 to 25 +/- 2.8 mm (mean +/- SD, p less than .001). The anterior angles at the commissure increased from 33 +/- 6 to 57 +/- 20 degrees (p less than .05) and the posterior angles from 36 +/- 9 to 54 +/- 14 degrees (p less than .05). The MVA was greater after CBV in patients with pliable mitral valves (2.6 +/- 0.7 cm2) compared with those with rigid mitral valves (1.9 +/- 0.8 cm2; p = .08). After CBV, MVA was smaller in patients with calcification (2.1 +/- 0.2 cm2) compared with those without (2.7 +/- 0.5 cm2; p = .10) and in those with subvalvular disease (2.0 +/- 0.6 cm2) compared with those without (2.9 +/- 0.9 cm2;p = .03). The MVA by Doppler ultrasound before CBV (1.0 +/- 0.2 cm2) correlated well with MVA by cardiac catheterization (1.0 +/- 0.3 cm2; r = .8, SEE = 0.2 cm2). After CBV, the correlation of MVA by Doppler ultrasound (2.0 +/- 0.5 cm2) with MVA by cardiac catheterization (2.4 +/- 0.8 cm2) was poor (r = .3, SEE = 0.44 cm2).(ABSTRACT TRUNCATED AT 250 WORDS)

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call