Abstract

AbstractSummary: Thin ppHMDSO plasma polymer films deposited in a low pressure hexamethyldisiloxane plasma have been exposed to oxygen plasmas ignited in the same reactor at different pressures. The time evolution of the ppHMDSO film during the oxygen plasma treatment (30 s to one hour) was monitored in situ by multi‐wavelength ellipsometry. The treated films were analysed ex situ by X‐ray reflectometry, spectroscopic ellipsometry and infrared spectroscopy. On the other hand, the oxygen atom density as well as the oxygen ion density and energy were measured by actinometry and Langmuir probe measurements, respectively. For all the investigated oxygen plasma conditions, the film thickness and extinction coefficient significantly decrease. If the O ion energy is low enough (typically less than 10 eV) the 65nm ppHMDSO can even be transformed into a 45 nm‐thick carbon free SiO2‐like film. In contrast, if the ion energy is higher than 10 eV, the ppHMDSO is only partially oxidised. Based on the oxygen atom flux measurement, it is concluded that the number of oxygen atoms impinging on the ppHMDSO film is not the only parameter which governs the treatment. The oxygen ion energy appears to have a key role as far as energetic ions are likely to induce the formation of a dense superficial SiO2 layer which prevents the diffusion of O atoms in the film and the out diffusion of volatile oxidation products. magnified image

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call