Abstract

In this paper, the failure mechanism under transient thermal cycle loading is studied for a functionally graded thermal barrier coating (FGTBC) system consisting of ZrO2 and NiCrAl plasma sprayed on a steel substrate. Controlled experiments and numerical analysis (thermoelastic finite element method) were performed and the results indicate that the surface tensile stress is responsible for the initiation of surface cracks and the tensile stress normal to the interface is large enough to break the interfacial bond (the magnitude of the interfacial bond strength of the ZrO2 layer in the FGTBC is below the strength of the ZrO2 , i.e. the interface is weaker than the ZrO2 material). By comparing the mode I stress intensity factor and the fracture toughness, the surface cracks are considered to be arrested, this characteristic is confirmed by SEM studies. The interfacial crack propagation causes a segment of the ZrO2 layer in the FGTBC to spall.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.