Abstract
Residual stress reduction in low alloy steel by a low frequency alternating magnetic treatment and its mechanism were investigated. Experimental results revealed that average stress reductions of 20%-24% were obtained in the welded samples. Moreover, compared with the zones with lower initial stress levels, more remarkable stress reductions were obtained in the stress concentration zones. The microstructures and magnetic domains were observed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). Based on the analysis of the microstructure and magnetic domain changes, the mechanism of stress reduction by the magnetic treatment has been concluded: (1) the magneto-plastic deformations mainly due to the more uniform redistribution of dislocations are the fundamental cause of stress relaxation; and (2) surface topography is also proved to affect the magnetic treatment results to some degree by influencing magnetic domains.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.